STRUCTODEK HD is not only an integral roofing system component; it also makes roofing easier with physical properties that generate structural rigidity and dimensional..." /> <

BLUE RIDGE FIBERBOARD -betway sports login High-Density Roofing Board

DOWNLOADS


betway sports login is not only an integral roofing system component; it also makes roofing easier with physical properties that generate structural rigidity and dimensional stability.


Category: Search Resul | Search Results for Cate | Search Results for Cate...

MasterFormat: 06 10 00 - Rough | 06 16 00 - | Fiberboard Sheets*...



BLUE RIDGE FIBERBOARD
250 Celotex Dr.
Danville, VA 24541
Tel: (866) 850-8834
Fax: (434) 799-5714

info@blueridgefiberboard.com

https://www.blueridgefiberboard.com/

Find a rep/distributor

Request More Info

DOWNLOADS

Related Products

    Overview


    betway sports login High-Density Roofing Board


    betway sports login is not only an integral roofing system component; it also makes roofing easier with physical properties that generate structural rigidity and dimensional stability.

    The wood fiberboard composition of betway sports login possesses natural bonding qualities, resulting in superior adhesion capabilities. Adhesive tightly grasps the fibers of betway sports login without causing excess absorption,
    providing a solid and secure roof system which bonds very well with many asphalt, coal tar, and cold-process adhesive products. The lightweight nature of betway sports login is better than heavier alternatives and will keep the roof load below the specified maximum weight.

    Uses
    betway sports login can be used as an insulation board, cover board, or re-roof/recover board. betway sports login is a high-density roofing board and is designed for low-slope applications and systems.

    Compliances
    • ASTM C 208, Type II, Grade 1 and Grade 2 betway sports login Insulation Board for Built-up and Single-Ply Roofing Systems
    • ASTM C 209, Test Methods
    • FM Approved as a component in Class 1 betway sports login systems per FM Standards 4450/4470
    • UL Classified to US Standard ANSI/UL 790 as a component in Class A rated betway sports login systems, reference TGFU.R20803
    • ULC Classified to Canadian Standard CAN/ULC-S107 as a component in Class A rated betway sports login systems, reference TGFU7.R20803
    • CAN/ULC-S706-09, Type II, Class 1 and Class 2 Roofboards for Built-up and Single-Ply Roofing Systems
    • Canadian Construction Materials Centre, Listing CCMC 13186-L
    • Miami-Dade County, Florida; NOA No.: 13-0626.02; Expiration Date 09/18/18
    • Florida Building Commission Product Approval # FL 13792

    Masterformat Number and Title
    07 22 16 - betway sports login Board Insulation

    Features/Benefits
    • Natural, Coated one side, or Integral coated six sides.
    • Proprietary coating is compatible with all single-ply membranes: TPO, PVC, EPDM.
    • Contributes to thermal insulation, 1.3 R-Value for ½” thick betway sports login .
    • UL and ULC Classified in Class A rated betway sports login systems. See complete marking on product.
    • FM Approved in Class 1 and Class A betway sports login systems. See www.roofnav. com for FM Approvals.
    • High Compressive Strength 48 psi @ 15% deformation.
    • Superior adhesion without excess absorption.
    • Easily handles hot asphalt, non-blistering.
    • Cuts with a standard utility knife.
    • Lightweight and easy to install, without the irritating fiberglass dust of glass-mat faced gypsum board.

    Leed Information
    May help contribute to LEED credits:
    • MR Credit 2: Construction Waste Management
    • MR Credit 4: Recycled Content
    • MR Credit 5: Regional Materials
    • MR Credit 6: Rapidly Renewable Materials
    • IEQ Credit 4.4: Low-Emitting Materials

    Precautions
    • Do not expose to open flame or excessive heat. May smolder if ignited. If ignited, extinguish completely.
    • Do not apply flame directly to betway sports login when installing a modified bitumen system.
    • betway sports login must not be used in close proximity to chimneys, heater units, fireplaces, steam pipes, or other surfaces which could provide long-term exposure to excessive heat (above 212° F) without adequate thermal protection. Consult appropriate heating appliance manufacturer’s instructions before installation.
    • Do not use as an underlayment for shingles.
    • Stagger joints among insulation layers and within layers.
    • Fastening patterns and densities will vary based upon specific membrane manufacturer assemblies. Refer to membrane manufacturer for fastening requirements.
    • Refer to FM RoofNav and/or membrane manufacturer for specific assembly requirements.
    • Moisture conditions may affect the performance of the product and the installation of the betway sports login system.
    • betway sports login must be kept dry at all times; in storage and during application. Store at a location where humidity and temperature duplicates those during installation.
    • Deck and substrates must be dry at start of application and maintained in a dry condition throughout installation.
    • Avoid application during rain, heavy fog, dew and any other conditions that may deposit moisture on surfaces.
    • Conduct a moisture survey on recovers and tear-offs to ensure the betway sports login deck is dry.
    • Before applying betway sports login , existing roof surfaces must be cleared of all gravel, dirt and debris which could hold moisture or present surface irregularities. All wet areas in old roof should be cut out and replaced.
    • Apply only as much betway sports login in one day as can be covered by completed roofing system that day.
    • BLUE RIDGE FIBERBOARD will not be responsible for deficiencies in design, construction, or workmanship, and for product moisture exposure before, during or after installation; including construction generated moisture.


    See More


    Specifications

    Physical Property½” Values1″ Values
    Thickness+ or - 10%+ or - 7%
    Transverse Strength, min, lbf12 - 1424
    Tensile Strength Parallel. min, lbf/in²150150
    Tensile Strength Perpendicular, min, lbf/ft²600600
    Water Absorption by volume, max, %77
    Moisture Content by weight, max, %1010
    Linear Expansion 50-90% RH, max, %0.50.5
    Modulus of Rupture, min, lbf/in²275140
    Deflection at Specified Min. Load, max, in.0.750.42
    Density, nominal, lb/ft³1616
    Flute Span, max width, in.1-5/82-5/8
    Compressive Strength, min, lbf/in²1515
    R- Value, ft²·h·ºF/BTU in1.32.5